{"product_id":"multimetr-uni-t-ut196","title":"Multimeter UNI-T  UT196","description":"This product comes with a 3-year warranty.\u003cbr\/\u003e\u003cbr\/\u003eThe solar multimeter UT196 True RMS by UNI-T is a professional product for professionals installing or maintaining photovoltaic or wind power plants. The design of the device enables work in a harsh outdoor environment - it has IP65 protection and is able to withstand a fall from a height of 2m. This multimeter measures DC voltage up to 1700 V, AC voltage (true rms) up to 1500 V at a frequency range of 45 to 1000 Hz. With the additional current loop UT-CS09D Flex enables non-contact measurement of AC currents from 1.5 to 3000 A, even in confined spaces. Furthermore, the UT196 measures frequency, resistance, capacity, semiconductor transitions and continuity of electric circuits.\u003cbr\/\u003eThe low-pass function allows you to filter out RF interference generated by the inverter. Low impedance mode can help troubleshoot sensitive circuits as well as circuits that may contain spurious voltages. A built-in flashlight, bright backlight, and audible and visual alarms allow users to complete work safely and efficiently even in dark and noisy environments.\u003cbr\/\u003eThe UT196 Solar Digital Multimeter is designed with 1700V DC, 1500Vrms AC overload protection and tested for safe use in a CAT III 1000V, CAT IV 600V environment and certified to CE, UKCA, cETLus.\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003eProduct parameters :\u003cbr\/\u003e\u003cbr\/\u003e- multifunctional multimeter with a focus on outdoor and indoor installations of photovoltaic and wind power plants\u003cbr\/\u003e- measurement of AC\/DC voltage, resistance, capacity, frequency, diodes, continuity of circuits, with external current loop and AC current\u003cbr\/\u003e- display: LCD, dual, backlit\u003cbr\/\u003e- maximum displayed value on the display: \t\t± 6000, values are updated 2 to 3 times per second\u003cbr\/\u003e- analog bar graph: \t\t\t\t\tyes, 31 segments, measurement speed 30 times per second\u003cbr\/\u003e- range switching: \t\t\t\t\tautomatic \/ manual\u003cbr\/\u003e- automatic identification of AC\/DC voltage: \t\tyes\u003cbr\/\u003e- contactless measurement elmag. field (NCV): \t\tyes\u003cbr\/\u003e- test of diodes (semiconductor junctions): \t\tyes, open circuit voltage approx. 3V\u003cbr\/\u003e- electrical circuit continuity test: \t\t\tyes, the circuit is considered closed when R ? 10?, then the buzzer beeps\u003cbr\/\u003e- built-in low frequency filter (LPF): \t\t\tyes, when LPF is on, interfering voltages above 1.2kHz are attenuated with ? -3db attenuation relative to 60Hz.\u003cbr\/\u003e- measurement in relative mode: \t\t\tyes\u003cbr\/\u003e- retention of peak values (Peak Hold): \t\t\tyes\u003cbr\/\u003e- display freeze (Data Hold): \t\t\t\tyes\u003cbr\/\u003e- Max\/Min mode: \t\t\t\t\tyes\u003cbr\/\u003e- power supply: \t\t\t\t\t9V \/ 6F22 battery,\u003cbr\/\u003e- low battery indication: \t\t\t\tyes, when the voltage drops below \u003c7.5V\u003cbr\/\u003e- automatic switch-off during inactivity: \t\t\tyes, after 15 minutes\u003cbr\/\u003e- built-in flashlight: \t\t\t\t\tyes\u003cbr\/\u003e- sound and visual indication: \t\t\t\tyes\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003eTechnical parameters :\u003cbr\/\u003e\u003cbr\/\u003eMeasurement of DC voltage (V): Range \/ Resolution \/ Accuracy\u003cbr\/\u003e600.0mV \/ 0.1mV \/ ±(0.5%+5)\u003cbr\/\u003e6.000V \/ 0.001V \/ ±(0.2%+5)\u003cbr\/\u003e60.00V \/ 0.01V \/ ±(0.2%+5)\u003cbr\/\u003e600.0V \/ 0.1V \/±(0.2%+5)\u003cbr\/\u003e1700V \/ 1V \/ ±(0.2%+5)\u003cbr\/\u003eThe input impedance on the mV\/DC range is approx. 1G?.\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003eMeasurement of AC voltage (V): Range \/ Resolution \/ Accuracy\u003cbr\/\u003e600.0mV \/ 0.1mV \/ 45Hz to 500Hz: ± (0.8%+3); 500Hz to 1kHz: ± (1.8%+3)\u003cbr\/\u003e6.000V \/ 0.001V \/ 45Hz to 500Hz: ± (0.8%+3); 500Hz to 1kHz: ± (1.8%+3)\u003cbr\/\u003e60.00V \/ 0.01V \/ 45Hz to 500Hz: ± (0.8%+3); 500Hz to 1kHz: ± (1.8%+3)\u003cbr\/\u003e600.0V \/ 0.1V \/ 45Hz to 500Hz: ± (0.8%+3); 500Hz to 1kHz: ± (1.8%+3)\u003cbr\/\u003e1500V \/ 1V \/ 45Hz to 500Hz: ± (0.8%+3); 500Hz to 1kHz: ± (1.8%+3)\u003cbr\/\u003eThe input impedance on the mV\/AC range is approx. 10M?.\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003eAutomatic AC\/DC voltage measurement: auto range \/ Resolution \/ Accuracy\u003cbr\/\u003e0V to 600.0V \/ 0.1V \/ DC to 500Hz: ± (2.0%+3); 500Hz to 1kHz: ± (4.0%+3)\u003cbr\/\u003eWith automatic range selection, LPF, Peak Hold selection is not possible, input impedance is 2M?\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003eResistance measurement: Range \/ Resolution \/ Accuracy\u003cbr\/\u003e600.0? \/ 0.1? \/± (1.0%+2)\u003cbr\/\u003e6,000k? \/ 1? \/ ± (0.8%+2)\u003cbr\/\u003e60.00k? \/ 10? \/ ± (0.8%+2)\u003cbr\/\u003e600.0k? \/ 100? \/ ± (0.8%+2)\u003cbr\/\u003e6,000M? \/ 1k? \/ ± (1.2%+3)\u003cbr\/\u003e60.00M? \/ 10k? \/ ± (2.5%+5)\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003eCapacitance measurement: Range \/ Resolution \/ Accuracy\u003cbr\/\u003e60.00nF\/ 0.01nF \/ in REL mode: ± (3%+10)\u003cbr\/\u003e600.0nF \/ 0.1nF \/ ± (1.9%+5)\u003cbr\/\u003e6.000µF \/ 0.001µF \/ ± (1.9%+5)\u003cbr\/\u003e60.00µF \/ 0.01µF \/ ± (1.9%+5)\u003cbr\/\u003e600.0µF \/ 0.1µF \/ ± (1.9%+5)\u003cbr\/\u003e6.000mF \/ 0.001mF \/ ± (5%+5)\u003cbr\/\u003e60.00mF \/ 0.01mF \/ ± (5%+5)\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003eMeasurement of AC currents with a current loop UT-CS09D Flex: Range \/ Resolution \/ Accuracy\u003cbr\/\u003e30.00A \/ 0.01A \/ ± (0.8%+8)\u003cbr\/\u003e300.0A \/ 0.1A \/ ± (0.8%+8)\u003cbr\/\u003e3000A \/ 1A \/ ± (0.8%+8)\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003eFrequency measurement: Range \/ Resolution \/ Accuracy\u003cbr\/\u003e60.00Hz to 1.000MHz \/ 0.1Hz to 0.001MHz \/ ± (0.08% +4)\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003eOther parameters :\u003cbr\/\u003e\u003cbr\/\u003e- operating temperature: \t\t\t\t0°C - 40°C (32°F - 104°F)\u003cbr\/\u003e- storage temperature: \t\t\t\t-10°C - 50°C (14°F - 122°F)\u003cbr\/\u003e- relative humidity: \t\t\t\t\t?75% RH (0°C - 30°C), ?50% RH (30°C - 40°C)\u003cbr\/\u003e- operating height: \t\t\t\t\t?2000m\u003cbr\/\u003e- EMC immunity: \t\t\t\t\tin accordance with EN61326-1: 2013, EN61326-2-2: 2013\u003cbr\/\u003e- power supply: \t\t\t\t\t9V \/ 6F22 battery\u003cbr\/\u003e- external dimensions: \t\t\t\t195 x 95 x 58 mm\u003cbr\/\u003e- weight: \t\t\t\t\t\t485g\u003cbr\/\u003e- IP protection: \t\t\t\t\tIP65\u003cbr\/\u003e- drop test: \t\t\t\t\t2m\u003cbr\/\u003e- certification: \t\t\t\t\tCE, UKCA, cETLus (CAT III 1000V, CAT IV 600V)\u003cbr\/\u003e- according to standards: \t\t\t\tEN61010-1, EN61010-2-033, EN\/IEC 61010-031\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003eContents of individual packaging :\u003cbr\/\u003e\u003cbr\/\u003e- multimeter UT196 Solar PRO: \t\t\t\t1 pc\u003cbr\/\u003e- test cables: \t\t\t\t\t1 pair\u003cbr\/\u003e- battery 9V\/ 6F22: \t\t\t\t\t1 pc\u003cbr\/\u003e- instructions for use: \t\t\t\t1 pc\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003eManufacturer:\u003cbr\/\u003eUNI-TREND\u003cbr\/\u003e- www.uni-t.cz","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":52555118575954,"sku":"07720296","price":2999.0,"currency_code":"CZK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/9624\/1490\/files\/07720296_17770dc5-8740-4743-b027-871cffecaa34.png?v=1776147024","url":"https:\/\/tipa-production.myshopify.com\/en\/products\/multimetr-uni-t-ut196","provider":"TIPA","version":"1.0","type":"link"}