{"product_id":"multimetr-uni-t-ut60eu","title":"Multimeter UNI-T  UT60EU","description":"This product comes with a 3-year warranty.\u003cbr\/\u003e\u003cbr\/\u003eThe UT60EU is a digital multimeter with a display range of 9999, which enables the measurement of real RMS voltage and current values with automatic and manual range selection. It has 1000V rms overload protection on all ranges, the current range is protected by a 10A \/ 1000V, 6.35 x 32mm tube fuse. If you approach the limit values ?990.0V \/ ?9.900A when measuring voltages and currents, an alarm will sound and \"OL\" will be displayed when the limit values are exceeded. Furthermore, it enables the measurement of resistance, capacity, temperature, frequency, duty cycle, continuity of circuits and semiconductor junctions. The circuit for non-contact electric field measurement in two sub-ranges is optimized. The multimeter is equipped with a modern processor with a fast analog-to-digital converter (conversion 3 times\/s).\u003cbr\/\u003e\u003cbr\/\u003eThe entire structure of the multimeter is equipped with a durable cover with double insulation and has European CE certification and meets the CAT II 1000V\/CAT III 600V safety classification. The device is suitable both for work in a laboratory or workshop, as well as for ordinary electrical practice. It is powered by ordinary batteries 3 x 1.5V, AAA, which last up to 500 hours thanks to low consumption.\u003cbr\/\u003e\u003cbr\/\u003eProduct parameters:\u003cbr\/\u003e\u003cbr\/\u003e- range of backlit display: 9999\u003cbr\/\u003e- voltage measurement: up to ±1000V \/ DC \/ AC rms\u003cbr\/\u003e- current measurement: up to ± 10A \/ DC \/ AC rms\u003cbr\/\u003e- resistance measurement: up to 99.99M?\u003cbr\/\u003e- capacity measurement: up to 9.999mF\u003cbr\/\u003e- temperature measurement: with supplied K-type probe up to 250°C\u003cbr\/\u003e- frequency measurement: up to 9.999MHz\u003cbr\/\u003e- duty cycle measurement: up to 1kHz\u003cbr\/\u003e- measurement modes: auto \/ manual \/ REL \/ RMS \/ HOLD \/ NCV EFLo \/ NCV EFHi\u003cbr\/\u003e- measurement of circuit continuity\u003cbr\/\u003e- measurement of semiconductor junctions\u003cbr\/\u003e- non-contact NCV measurement\u003cbr\/\u003e- optical and acoustic alarms\u003cbr\/\u003e- protection of voltage inputs against overload above 1000V\u003cbr\/\u003e- protection of current input 10A by fast fuse\u003cbr\/\u003e- input impedance approx. 10M? for DCV, then 3G? on the DCmV range\u003cbr\/\u003e- power supply: 3 x 1.5V, AAA\u003cbr\/\u003e- consumption v low energy consumption during measurement: about 2 mA\u003cbr\/\u003e- consumption in sleep mode: \u003c 30 µA\u003cbr\/\u003e- operation on one set of batteries: 500 hours\u003cbr\/\u003e- low battery indication: yes\u003cbr\/\u003e- automatic shutdown (sleep during inactivity): yes, after 15 minutes\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003eTechnical parameters :\u003cbr\/\u003e\u003cbr\/\u003e- DC voltage measurement (input impedance is about 3G? on the DCmV range, 10M? on the other ranges):\u003cbr\/\u003e             (range \/ resolution \/ accuracy)\u003cbr\/\u003e          9.999mV \/ 0.001mV \/ ± (0.7% + 8)\u003cbr\/\u003e          99.99 mV \/ 0.01 mV \/ ± (0.7% + 8)\u003cbr\/\u003e          999.9 mV \/ 0.1 mV \/ ± (0.5% + 3)\u003cbr\/\u003e          9.999 V \/ 0.001 V \/ ± (0.5% + 3)\u003cbr\/\u003e          99.99V \/ 0.1V \/ ± (0.5% + 3)\u003cbr\/\u003e          999.9V \/ 0.1V \/ ± (0.5% + 3)\u003cbr\/\u003e- Maximum input voltage: ±1000V, alarm sounds at 990.0V, \"OL\" is displayed at \u003e1000V.\u003cbr\/\u003e- 1000V RMS (DC\/AC) overload protection\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e- Measurement of AC voltage (input impedance approx. 10M?, ):\u003cbr\/\u003e                   ( range \/ resolution \/ accuracy in the range 40Hz to 400Hz, sine RMS )\u003cbr\/\u003e                 9.999mV \/ 0.001mV \/ ± (1% + 3)\u003cbr\/\u003e                 99.99 mV \/ 0.01 mV \/ ± (1% + 3)\u003cbr\/\u003e                 999.9 mV \/ 0.1 mV \/ ± (0.8% + 3)\u003cbr\/\u003e                 9.999 V \/ 0.001 V \/ ± (0.8% + 3)\u003cbr\/\u003e                 99.99V \/ 0.1V \/ ± (0.8% + 3)\u003cbr\/\u003e                 999.9V \/ 0.1V \/ ± (0.8% + 3)\u003cbr\/\u003e- Maximum input voltage: AC1000V, alarm sounds at 990.0V, \"OL\" is displayed at \u003e1000V.\u003cbr\/\u003e- 1000V RMS (DC\/AC) overload protection\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e- DC current measurement:\u003cbr\/\u003e         ( range \/ resolution \/ accuracy )\u003cbr\/\u003e        999.9 µA \/ 0.1 µA \/ ± (0.8% + 3)\u003cbr\/\u003e        999.9mA \/ 0.1mA \/ ± (1.0% + 3)\u003cbr\/\u003e        9.999 A \/ 0.001 A \/ ± (1.0% + 3)\u003cbr\/\u003eAlarm will sound at ?9.900A, \"OL\" will be displayed at \u003e10.00A\u003cbr\/\u003eOverload Protection: 1000V RMS, 10A fast-blow fuse\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e- AC current measurement:\u003cbr\/\u003e         ( range \/ resolution \/ accuracy in the range 40Hz to 400Hz )\u003cbr\/\u003e        999.9 µA \/ 0.1 µA \/ ± (1.0% + 3)\u003cbr\/\u003e        999.9mA \/ 0.1mA \/ ± (1.2% + 3)\u003cbr\/\u003e        9.999 A \/ 0.001 A \/ ± (1.2% + 3)\u003cbr\/\u003eAlarm will sound at ?9.900A, \"OL\" will be displayed at \u003e10.00A\u003cbr\/\u003eOverload Protection: 1000V RMS, 10A fast-blow fuse\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e- Resistance measurement:\u003cbr\/\u003e         ( range \/ resolution \/ accuracy )\u003cbr\/\u003e           999.9 ? \/ 0.1 ? \/ ± (0.8% + 2)\u003cbr\/\u003e         9.999k? \/ 0.001k? \/ ± (0.8% + 2)\u003cbr\/\u003e         99.99 k? \/ 0.01 k? \/ ± (0.8% + 2)\u003cbr\/\u003e         999.9 k? \/ 0.1 k? \/ ± (0.8% + 2)\u003cbr\/\u003e        9.999 M? \/ 0.001 M? \/ ± (1.5% + 3)\u003cbr\/\u003e        99.99 M? \/ 0.01 M? \/ ± (2.0% + 5)\u003cbr\/\u003e1000V overload protection\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e- Measurement of capacitor capacity:\u003cbr\/\u003e               ( range \/ resolution \/ accuracy )\u003cbr\/\u003e                9.999 nF \/ 0.001 nF \/ ± (4% + 10)\u003cbr\/\u003e                99.99 nF \/ 0.01 nF \/ ± (4% + 5)\u003cbr\/\u003e                999.9 nF \/ 0.01 nF \/ ± (4% + 5)\u003cbr\/\u003e                9.999 µF \/ 0.001 µF \/ ± (4% + 5)\u003cbr\/\u003e                99.99 µF \/ 0.01 µF \/ ± (4% + 5)\u003cbr\/\u003e                999.9 µF \/ 0.1 µF \/ ± (4% + 5)\u003cbr\/\u003e               9.999 mF \/ 0.001 mF \/ ± (10%)\u003cbr\/\u003eFor capacitances ?100nF, use REL mode\u003cbr\/\u003e1000V overload protection\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e- Frequency measurement:\u003cbr\/\u003e                          ( range \/ resolution \/ accuracy )\u003cbr\/\u003e  99.99 Hz to 9.999 MHz \/ 0.01 Hz to 0.001 MHz \/ ± (0.1% + 5)\u003cbr\/\u003e1000V RMS (DC\/AC) overload protection\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e- Duty cycle measurement for square waves ?10kHz:\u003cbr\/\u003e   ( range \/ resolution \/ accuracy )\u003cbr\/\u003e           0.1 to 99.9% \/ 0.1% \/ ± (3% + 5)\u003cbr\/\u003e1000V RMS (DC\/AC) overload protection\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e  - Diode test:\u003cbr\/\u003evoltage at terminals without load about 3.3 V\u003cbr\/\u003ethe voltage drop across a good silicon junction is 0.5 to 0.8 V\u003cbr\/\u003emeasurement resolution 0.001 V\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e- Circuit Continuity Test:\u003cbr\/\u003ethe buzzer tone will not sound if the resistance is greater than 30 ?\u003cbr\/\u003ea tone will sound if the resistance is less than 30 ?\u003cbr\/\u003e1000V RMS (DC\/AC) overload protection\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e- Temperature measurement:\u003cbr\/\u003e( range \/ resolution \/ accuracy )\u003cbr\/\u003e             -40°C to 0°C \/ 1°C \/ ± 4°C\u003cbr\/\u003e            0°C to 100°C \/ 1°C \/ ± (1.0% + 5)\u003cbr\/\u003e      100°C to 1000°C \/ 1°C \/ ± (2.0% + 5)\u003cbr\/\u003e\u003cbr\/\u003e             -40°F - 32°F \/ 1°F \/ ± 5°F\u003cbr\/\u003e          \u003e32°F - 212°F \/ 1°F \/ ± (1.5% + 5)\u003cbr\/\u003e      \u003e212°F - 1832°F \/ 1°F \/ ± (2.5% + 5)\u003cbr\/\u003eThe accessory type K thermocouple is only usable for temperature measurements below 250°C\/482°F.\u003cbr\/\u003e1000 V RMS (DC\/AC) overload protection\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003eGeneral characteristics:\u003cbr\/\u003e\u003cbr\/\u003e- ambient working temperature: 0°C to 40°C\u003cbr\/\u003e- storage temperature: -10°C – 50°C (14°F – 122°F)\u003cbr\/\u003e- working relative humidity: ?75% (0°C to 30°C), ?50% (30°C to 40°C)\u003cbr\/\u003e- working altitude: 0 to 2000m\u003cbr\/\u003e- environment of use: indoor use\u003cbr\/\u003e- resistance to EMC: for radio frequency field 1V\/m\u003cbr\/\u003e- power supply: 3 x 1.5V, AAA\u003cbr\/\u003e- LCD display: 73 mm x 50 mm with backlight, 2 levels of brightness, or off\u003cbr\/\u003e- product color: red and gray\u003cbr\/\u003e- net weight of the product: 290 g\u003cbr\/\u003e- product weight: about 400g (including batteries)\u003cbr\/\u003e- product size: 169 x 81 x 46 mm\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003eContents of individual packaging:\u003cbr\/\u003e\u003cbr\/\u003e- multimeter UT60EU with storage case: 1 pc\u003cbr\/\u003e- battery 1.5V, AAA: 3 pcs\u003cbr\/\u003e- fuse F1: F 10A \/250V (6.35 x 32mm) - in the device: 1pc\u003cbr\/\u003e- test cables with spikes in CAT II 1000V\/CAT III 600V category: 1 pair\u003cbr\/\u003e- temperature probe: 1 pc\u003cbr\/\u003e- instructions for use: 1 pc\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003eWholesale packing:\u003cbr\/\u003e\u003cbr\/\u003e- standard quantity in a carton: 20 pcs\u003cbr\/\u003e- size of standard cardboard: 420 x 320 x 300 mm\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e- Manufacturer: UNI-TREND\u003cbr\/\u003e- www.uni-t.cz","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":52557103989074,"sku":"07720301","price":869.0,"currency_code":"CZK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/9624\/1490\/files\/07720301.png?v=1776147486","url":"https:\/\/tipa-production.myshopify.com\/en\/products\/multimetr-uni-t-ut60eu","provider":"TIPA","version":"1.0","type":"link"}