{"product_id":"tester-multifunkcni-uni-t-ut595","title":"Multipurpose Electrical Tester UNI-T UT595","description":"The UT 595 is a universal measuring and testing device for performing inspections of electrical appliances. It enables automated control of tripping time of circuit breakers, measurement of leakage currents, measurement of earth loop impedance and ground continuity, measurement of insulation resistance, measurement of AC voltage frequency and measurement of DC and AC voltage, phase sequence in three-phase distributions.\u003cbr\/\u003eThe device is designed with a new look, with a large multifunction display with a bar indicator with fifty pieces. It has a durable cover and new analog, digital and microprocessor circuits.\u003cbr\/\u003eThis device has been designed, manufactured and tested according to the safety standard IEC61010 (Safety requirements for electrical equipment) in the CATIII 300V overvoltage category. It fully complies with the ČSN EN 61557 standard for measuring insulation and transient resistance.\u003cbr\/\u003eUT595 is the ideal tool for maintenance, testing and inspection of electrical protection elements for every electrician and inspection technician.\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003eProduct parameters :\u003cbr\/\u003e- maximum display: \t\t\t\t\t\t9999, analog bar 50 divisions\u003cbr\/\u003e- backlit LCD display with dimensions: \t\t\t\t125 mm × 37 mm\u003cbr\/\u003e- the display shows: \t\t\t\t\t\tfunction modes, values, units and symbols\u003cbr\/\u003e- function switching: \t\t\t\t\trotary 15-position switch\u003cbr\/\u003e- range switching: \t\t\t\t\t\tautomatic\u003cbr\/\u003e- current measurement of current protectors: \t\t\ttypes 10mA, 30mA, 100mA, 300mA, 500mA\u003cbr\/\u003e- possibility of changing the phase angle 0 ° \/ 180 ° to detect the fastest time of protector equipment\u003cbr\/\u003e- optional half-wave \/ full-wave test mode and countdown (30sec)\u003cbr\/\u003e- automatic tests of circuit breakers: sequential switching of leakage currents, smooth rise of leakage current up to the circuit breaker equipment\u003cbr\/\u003e- storage of measured values ??in memory\u003cbr\/\u003e- loop impedance \/ fault current (PFC) \/ short circuit current (PSC) test: \tin the range 0.05? to 2000?\u003cbr\/\u003e- earth continuity measurement: \t\t\t\tin the range 0.01? to 200?\u003cbr\/\u003e- insulation resistance measurement: \t\t\t\t0.05 M? to 1M? at test voltage 250V \/ 500V \/ 1000V\u003cbr\/\u003e- AC voltage frequency measurement: \t\t\t\tin the range of 20Hz to 100Hz\u003cbr\/\u003e- AC and DC voltage measurement: \t\t\t\t0V to 440V, automatic AC \/ DC \/ polarity resolution\u003cbr\/\u003e- phase sequence measurement: \t\t\t\tphase sequence indication, direction of rotation\u003cbr\/\u003e- power supply: \t\t\t\t\t\t6 pcs alkaline batteries 1.5V AA\u003cbr\/\u003e- calibration protocol: \t\t\t\t\tmust be ordered separately\u003cbr\/\u003e- automatic switch-off of the device\u003cbr\/\u003e- key lock\u003cbr\/\u003e- an indispensable assistant for every inspection technician\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003eTechnical parameters :\u003cbr\/\u003e\u003cbr\/\u003e- Measurement of circuit breakers\u003cbr\/\u003e\u003cbr\/\u003emeasuring current selection I: \t\t\t\t\t10mA \/ 30mA \/ 100mA \/ 300mA \/ 500mA\u003cbr\/\u003emeasuring voltage: \t\t\t\t\t\t220V ± 10%, frequency 45Hz to 65Hz\u003cbr\/\u003emeasuring current accuracy at AC voltage 220V: \t\t\t± (10% + 2)\u003cbr\/\u003eautomatic circuit breaker test with current I: \t\t\t50%, 100%, 200%, 500% of tripping current\u003cbr\/\u003ecurrent measurement range at current 1 * I, ?n: \t\t\t0 to 2000ms\u003cbr\/\u003etime measuring range at current 1 * I, ?n: \t\t\t\t0 to 500ms (with countdown function)\u003cbr\/\u003etime measuring range at current 1 * I, ?n: \t\t\t\t0 to 300ms\u003cbr\/\u003etime measuring range at current 2 * I, ?n: \t\t\t\t0 to 200ms (with countdown function)\u003cbr\/\u003etime measuring range at current 2 * I, ?n: \t\t\t\t0 to 150ms\u003cbr\/\u003etime measuring range at current 5 * I, ?n: \t\t\t\t0 to 40ms\u003cbr\/\u003etime measurement accuracy: ± (5% + 5)\u003cbr\/\u003epossibility to change phase angle 0 ° \/ 180 °\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e- Loop \/ fault current (PFC) \/ short circuit current (PSC) measurement\u003cbr\/\u003e\u003cbr\/\u003eoperating voltage: \t\t\t\t\t\t220V ± 10% \/ 195V to 440V \/ 45Hz to 65Hz\u003cbr\/\u003emeasuring current and time: \t\t\t\t\t20A \/ 20ms\u003cbr\/\u003emeasuring ranges: \t\t\t\t\t\t0.05? to 1.99?; 2.0? to 19.9?; 20? to 2000?\u003cbr\/\u003elowest resolution: \t\t\t\t\t\t0.01?\u003cbr\/\u003eshort-circuit current: \t\t\t\t\t0kA to 26kA\u003cbr\/\u003eaccuracy: \t\t\t\t\t\t\t± (5% + 5)\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e- Earth continuity measurement\u003cbr\/\u003e\u003cbr\/\u003erated measuring voltage: \t\t\t\t\tapprox. 5V\u003cbr\/\u003emeasuring current: \t\t\t\t\t\tmore than 200mA\u003cbr\/\u003emeasuring range: \t\t\t\t\t\t0.01? to 200?\u003cbr\/\u003eaccuracy in the range 0.01? to 200?: \t\t\t\t± (2% + 5)\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e- Insulation resistance measurement\u003cbr\/\u003e\u003cbr\/\u003etest rated no-load voltage: \t\t\t\t\tDC 250V ± 10% or 500V ± 10% or 1000V ± 10%\u003cbr\/\u003emeasuring range: \t\t\t\t\t\t0.05 to 250M?, or 0.05 to 500M?, or 0.05 to 1000M?\u003cbr\/\u003erated measuring current at 250k?, 500k? or 1M? load: \t\t0.9mA to 1.1mA\u003cbr\/\u003eshort-circuit current: \t\t\t\t\t\u003c1.8mA\u003cbr\/\u003emeasurement accuracy in the range 0.05M? to 1000M?: \t\t± (5% + 5)\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e- AC and DCV voltage measurement\u003cbr\/\u003e\u003cbr\/\u003eDC measuring range: \t\t\t\t\t0 to ± 440V\u003cbr\/\u003eAC measuring range: \t\t\t\t\t0 to 440V (50 \/ 60Hz)\u003cbr\/\u003eresolution: \t\t\t\t\t\t1V\u003cbr\/\u003emeasurement accuracy: \t\t\t\t\t± (2% + 3)\u003cbr\/\u003evoltage measurement in the range \u003c10V: \t\t\t\tinformative only\u003cbr\/\u003e \u003cbr\/\u003e\u003cbr\/\u003e- Frequency measurement\u003cbr\/\u003e\u003cbr\/\u003emeasuring range: \t\t\t\t\t\t20Hz to 100Hz\u003cbr\/\u003eresolution: \t\t\t\t\t\t1Hz\u003cbr\/\u003eMeasurement accuracy: \t\t\t\t\treference only\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e- Phase sequence measurement\u003cbr\/\u003e\u003cbr\/\u003efor voltage: \t\t\t\t\t\tthree-phase AC 100V to 440V \/ 45 to 65Hz\u003cbr\/\u003ephase sequence: \t\t\t\t\t\tL1 › L2 › L3 forward rotation; L1 › L2 › L3 reverse rotation\u003cbr\/\u003ephase voltage drop: \t\t\t\t\t\tphase drop L1, L2 or L3 will be displayed on the LCD\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003eGeneral parameters :\u003cbr\/\u003e\u003cbr\/\u003e- automatic range selection function: \t\t\t\tyes\u003cbr\/\u003e- low battery indication: \t\t\t\t\tyes, symbol \"\" on the display\u003cbr\/\u003e- overload indication (out of range): \t\t\t\tyes, \"OL\" symbol on the display\u003cbr\/\u003e- power supply: \t\t\t\t\t\t1.5V AA batteries, 6 pieces\u003cbr\/\u003e- current consumption: \t\t\t\t\tbasic approx. 10mA, approx. 50mA at 1000V range\u003cbr\/\u003e- LCD display dimensions: \t\t\t\t\t125 × 37 mm\u003cbr\/\u003e- working environment: \t\t\t\t\ttemperature 0 ° C to + 40 ° C, humidity max. 85% RH\u003cbr\/\u003e- the stated accuracy is guaranteed in the environment: \t\ttemperature 23 ± 5 ° C, humidity: 45-75% RH\u003cbr\/\u003e- storage environment: \t\t\t\t\ttemperature -20 ° C to + 60 ° C, humidity max. 90% RH\u003cbr\/\u003e- weight: \t\t\t\t\t\t\t1 kg (including batteries)\u003cbr\/\u003e- device dimensions: \t\t\t\t\t210 x 90 x 175 mm\u003cbr\/\u003e- device color: \t\t\t\t\t\tred and gray\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003eContents of individual packaging :\u003cbr\/\u003e\u003cbr\/\u003e- device UT595: \t\t\t\t\t\t1pc\u003cbr\/\u003e- test cables: \t\t\t\t\t\t3pcs (special red × 1, green × 1, black × 1)\u003cbr\/\u003e- alkaline battery 1.5V AA: \t\t\t\t\t6pcs\u003cbr\/\u003e- portable case: \t\t\t\t\t\t1pc\u003cbr\/\u003e- instructions for use: \t\t\t\t\t1pc\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003eWholesale packaging :\u003cbr\/\u003e\u003cbr\/\u003e- standard quantity per carton: \t\t\t\t\t4pcs\u003cbr\/\u003e- dimensions of the standard carton: \t\t\t\t510 × 330 × 300 mm\u003cbr\/\u003e- standard total carton weight: \t\t\t\t\t15 kg\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003eManufacturer: UNI-TREND\u003cbr\/\u003ewww.uni-t.cz\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e\u003cbr\/\u003e","brand":"UNI-T","offers":[{"title":"Default Title","offer_id":52541766730066,"sku":"07720149","price":12790.0,"currency_code":"CZK","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0954\/9624\/1490\/files\/07720149_0a4a063b-9a21-4d48-91e3-bda1c4b12dff.png?v=1776144986","url":"https:\/\/tipa-production.myshopify.com\/en\/products\/tester-multifunkcni-uni-t-ut595","provider":"TIPA","version":"1.0","type":"link"}