Timer switch programmable with relay
Wholesale price
Programovatelný časový spínač s relé - napájení 12V DC, releový výstup, 6 pracovních režimů (P1–P3) včetně jednorázového sepnutí, zpožděného sepnutí a cyklického opakování s nastavitelným počtem cyklů 1–999 nebo nekonečno, nastavitelné doby T1 a T2, spouštění vstupním impulsem, digitální displej, vhodný pro automatizaci a průmyslové aplikace
Will be restocked
Expected shipping:
17.09.2026
at our place
Regular price
45,00 Kč
37,19 Kč
excl. VAT
Unit price
/
Unavailable
TIPA | SKU:
09830311
Product description
Universal time switch with 12V relay output and a wide range of settings.
Working modes:
P1 – after the input pulse, the relay is switched on for the set time. This mode has even more setting options:
P1.1 – only the first trigger pulse is active
P1.2 – active every pulse after the set time
P1.3 – the first pulse starts the switch-on time countdown, with the next pulse, the switch-on time can be shortened even before the set time has expired.
P2 – after the input pulse, the module counts down the set time T1 ("CP" parameter), then turns on the relay for the set time T2 ("OP" parameter). This cycle will only happen once.
P3.1 – cyclic repetition of the P2 mode, while the number of cycles can be set to 1–999 or infinity ("LOP" parameter, infinity = — on the display) The first pulse starts everything, the next pulse disconnects the clock
P3.2 – P3.1 mode, but it is not necessary to start with an impulse. It is active as soon as the power is connected.
P4 – the relay switches on the rising edge of the pulse and the countdown is started by the falling edge of the pulse. This mode is used for delayed shutdown of appliances, e.g. when lighting the staircase.
Set parameters:
OP – relay switching time
CP – relay shutdown time
LOP – number of cycles (1–999× or infinity – display ---)
these parameters are independent, but shared by each mode, i.e. that they will be the same in each mode.
Setting the switch-on and switch-off time:
XX.X = 0.1 – 99.9 sec
XXX. = 1 – 999 sec
XXX = 1 – 999 min
e.g. for a time setting of 3.2 seconds, the display will show 03.2
the "SET" button is intended for setting all parameters. A short press activates the setting of OP, CL and LOP parameters, a long press activates modes P1 – P4. The selection is made with the "UP" and "DOWN" buttons.
Operating parameters:
Supply voltage 6-12V DC or Micro USB 5V (incorrectly printed 6-30V on the board)
Quiescent current 20mA, in active state 50mA
Trigger pulse 3–24V or GND (optional), the module is equipped with an optocoupler
Preservation of the set parameters even when the power is turned off
LED indication for switched on status
Working temperature -40°C ~ 85°C
Dimensions 62×38×17mm
COM is a contact that flips between NO and NC when voltage is applied to the coil.
The NO contact in the rest state is open compared to the COM contact
NC is a contact in the rest state connected to the COM contact
The relay contacts are not connected to any voltage.
The product is not an independently functional unit, it requires professional assembly.
Working modes:
P1 – after the input pulse, the relay is switched on for the set time. This mode has even more setting options:
P1.1 – only the first trigger pulse is active
P1.2 – active every pulse after the set time
P1.3 – the first pulse starts the switch-on time countdown, with the next pulse, the switch-on time can be shortened even before the set time has expired.
P2 – after the input pulse, the module counts down the set time T1 ("CP" parameter), then turns on the relay for the set time T2 ("OP" parameter). This cycle will only happen once.
P3.1 – cyclic repetition of the P2 mode, while the number of cycles can be set to 1–999 or infinity ("LOP" parameter, infinity = — on the display) The first pulse starts everything, the next pulse disconnects the clock
P3.2 – P3.1 mode, but it is not necessary to start with an impulse. It is active as soon as the power is connected.
P4 – the relay switches on the rising edge of the pulse and the countdown is started by the falling edge of the pulse. This mode is used for delayed shutdown of appliances, e.g. when lighting the staircase.
Set parameters:
OP – relay switching time
CP – relay shutdown time
LOP – number of cycles (1–999× or infinity – display ---)
these parameters are independent, but shared by each mode, i.e. that they will be the same in each mode.
Setting the switch-on and switch-off time:
XX.X = 0.1 – 99.9 sec
XXX. = 1 – 999 sec
XXX = 1 – 999 min
e.g. for a time setting of 3.2 seconds, the display will show 03.2
the "SET" button is intended for setting all parameters. A short press activates the setting of OP, CL and LOP parameters, a long press activates modes P1 – P4. The selection is made with the "UP" and "DOWN" buttons.
Operating parameters:
Supply voltage 6-12V DC or Micro USB 5V (incorrectly printed 6-30V on the board)
Quiescent current 20mA, in active state 50mA
Trigger pulse 3–24V or GND (optional), the module is equipped with an optocoupler
Preservation of the set parameters even when the power is turned off
LED indication for switched on status
Working temperature -40°C ~ 85°C
Dimensions 62×38×17mm
COM is a contact that flips between NO and NC when voltage is applied to the coil.
The NO contact in the rest state is open compared to the COM contact
NC is a contact in the rest state connected to the COM contact
The relay contacts are not connected to any voltage.
The product is not an independently functional unit, it requires professional assembly.