Time switch 0-999sec, 0-999min, 0-999h with two times

Časový spínač se dvěma časovými kanály - napájení 12V DC, kontakt relé 230VAC/10A nebo 12VDC/20A, 6 provozních režimů (trvalé sepnutí, časované sepnutí/vypnutí, kombinované a cyklické režimy), časový rozsah 0–999 s / 0–999 min / 0–999 hod, klidový odběr 20mA, odběr při sepnutém relé 120mA, rozměry 48 × 29 mm, montážní otvor 45,5 × 26 mm

In stock more than 5 pcs
Expected shipping: 15.06.2026
Regular price 144,00 Kč 119,01 Kč excl. VAT
TIPA  |  SKU: 09830218  |  Barcode: 8595563729168

Product description

Timer with three adjustable time intervals and two time channels. Both times can be combined differently. Time range 0–999sec, 0–999min, 0–999h, settings apply to both channels simultaneously.


Technical parameters:

- power supply: 12 V
- 6 operating modes - see below
- relay contact 230VAC / 10A or 12VDC / 20A
- dimensions: 48 × 29 mm
- consumption in idle mode: 20 mA
- consumption with closed relay: 120 mA
- panel opening: 45.5 × 26 mm

Operating modes:
- P1–0: the relay closes permanently after time T1 has elapsed
- P1–1: the relay is closed for T1, then it switches off permanently
- P1–2: the relay closes for time T2 after the time T1 has elapsed, then the module is idle
- P1–3: the relay is closed for T1, then it is switched off for T2 and then it closes permanently
- P1–4: the relay switches cyclically to time T2 after time T1 has elapsed - it is switched off at the beginning of the cycle
- P1–5: the relay switches cyclically for time T1 after the time T2 has elapsed - it is switched on at the beginning of the cycle

Time setting:
- P0–0 - setting to seconds mode
- P0–1 - setting to minute mode
- P0–2 -set to clock mode

Settings:
- a short press of the SET button activates the time setting mode:
- T1 - the red display flashes and the time T1 can be set with the arrows
- T2 - the green display flashes and the time T1 can be set with the arrows
- saving of set values ??is enabled by repeated short press SET or automatically after 6sec of inactivity
- long press of the SET button allows to set time units and operating modes:
-P0 - setting sec (0) - min (1) - hr (2) using the arrows. The settings apply to both channels at the same time
-P1 - setting of operating modes 0–5, see above, also with arrows.
- saving of set values ??is enabled by repeated short press SET or automatically after 6sec of inactivity

The module does not have a separate Start button. The timing starts by connecting the input voltage