Time switch 0-999sec, 0-999min, 0-999h with two times black

Časový spínač se dvěma časovými kanály - napájení 12V DC, kontakt relé 230VAC/10A nebo 12VDC/20A, 4 provozní režimy, časový rozsah 0–999 s / 0–999 min / 0–999 hod s individuálním nastavením každého kanálu, cyklický režim on/off, klidový odběr 15mA, odběr při sepnutém relé 60mA, rozměry 48 × 29 mm, hloubka 33 mm, montážní otvor 45,4 × 26 mm, barva černá

In stock more than 5 pcs
Expected shipping: 30.07.2026
Regular price 139,00 Kč 114,88 Kč excl. VAT
TIPA  |  SKU: 09830191  |  Barcode: 8595563729090

Product description

Time switch with two time channels. Both times can be combined with each other in different ways, seconds, minutes, hours can be set for both times, and this can also be combined with each other (for example, the switch-on time can be in hours and the switch-off time can be in seconds.


Specifications:
time range: 0–999sec, 0–999min, 0–999h, setting of each channel individually
power supply: 12V DC
operating modes: 4
relay contact 230VAC/10A or 12VDC/20A
dimensions 48×29mm
depth: 33mm
mounting hole: 45.4×26mm
consumption in idle mode: 15mA
consumption when the relay is switched on: 60mA


Operating modes:
P0 0 power-on timer runs in seconds
P0 1 power-on timer runs in minutes
P0 2 power-on timer runs in hours
P1 0 shutdown timer runs in seconds
P1 1 shutdown timer runs in minutes
P1 2 shutdown timer runs in hours
P2 on / off setting of cyclic repetition
P3 0 setting enabled, 1 setting locked


Time setting:
Enter the time setting – double-click the S button
005,000 turns on for five seconds and then turns off permanently
000 005 turns on permanently in five seconds
005 005 five seconds on, five seconds off, continuous repeat / P2 set on
005 005 five seconds off, five seconds on, continuous repeat / P2 set off

The module does not have a separate Start button. Timing starts by connecting the input voltage.

Reset running cycle and restart from the beginning Hold button 3 (scroll down) for 3 seconds

The product is not an independently functional unit, it requires professional assembly.

Product parameters