Digital thermostat and humidistat HX-M452, -50 to 110 ° C
Digitální termostat a hygrostat - napájení 12V DC, teplotní rozsah -40 až 120°C, rozsah vlhkosti 0 až 100% RH, rozlišení teploty 0,1°C, rozlišení vlhkosti 0,1% RH, čidlo SHT20, 2× relé s kontakty 250VAC/10A, režim topení i chlazení, regulace vlhkosti, rozměry 65 × 55 × 28 mm, vhodný pro líhně, terária a skleníky
In stock 2 pcs
Expected shipping:
15.06.2026
Regular price
225,00 Kč
185,95 Kč
excl. VAT
Unit price
/
Unavailable
HADEX | SKU:
09830171
Product description
Digital thermostat and humidistat module 2 in 1.
Technical parameters:
- working voltage: DC12V
- temperature measurement range: -40 ° C to 120 ° C
- humidity measuring range: 0-100% RH
- temperature measurement accuracy: 0.1 ° C
- resolution for humidity measurement: 0.1% RH
- T + H sensor: SHT20
- output: 2 × relays, contacts 250VAC / 10A
- dimensions: 65 × 55 × 28mm
Thermostat settings:
The temperature can be set for both heating and cooling mode. If T1 T2, then cooling mode is active.
Heating mode:
- Press for 3sec. + button in the thermostat section
- After the temperature display flashes, use the + or - buttons to set the lower limit for starting heating or cooling (temperature T1).
- Press for 3sec. button - in the thermostat section
- after the temperature display flashes, set the upper limit to stop heating or cooling (temperature T2) with the + or - buttons.
Humidity setting:
Like the temperature, the humidity can be set for both humidification and drying modes. If H1 H2, then the drying mode is active.
Technical parameters:
- working voltage: DC12V
- temperature measurement range: -40 ° C to 120 ° C
- humidity measuring range: 0-100% RH
- temperature measurement accuracy: 0.1 ° C
- resolution for humidity measurement: 0.1% RH
- T + H sensor: SHT20
- output: 2 × relays, contacts 250VAC / 10A
- dimensions: 65 × 55 × 28mm
Thermostat settings:
The temperature can be set for both heating and cooling mode. If T1
Heating mode:
- Press for 3sec. + button in the thermostat section
- After the temperature display flashes, use the + or - buttons to set the lower limit for starting heating or cooling (temperature T1).
- Press for 3sec. button - in the thermostat section
- after the temperature display flashes, set the upper limit to stop heating or cooling (temperature T2) with the + or - buttons.
Humidity setting:
Like the temperature, the humidity can be set for both humidification and drying modes. If H1