Thermostat AVANSA TH 1
Mechanický termostat - napájení 250V/16A, kontakt AG 1000/1000, rozsah provozní teploty +5 až +30°C, teplotní hystereze méně než 1°C, teplotní gradient 1°C/10 min, montáž na stěnu, zapojení dle přiloženého schématu, doporučená instalace min. 1,5 m od zdrojů tepla a přímého slunečního záření
Last piece
Expected shipping:
16.06.2026
Regular price
345,00 Kč
285,12 Kč
excl. VAT
Unit price
/
Unavailable
AVANSA | SKU:
08840282
Product description
Modern mechanical thermostat AVANSA TH1
Thermostat installation:
- the thermostat must be disconnected from the mains during installation
- reliable operation depends to a large extent on the correct mounting location
- the thermostat must be mounted in a place away from heat sources (radiator, television, refrigerator) and out of direct sunlight at least 1.5 m
- it is not recommended to install near the door, due to air flow
- the terminals of the connecting cables are located inside the thermostat
- to access the terminals, select the adjustment knob and remove the screws securing the cover
- connection is possible according to the enclosed diagram located in the package
Technical parameters:
- voltage: 16A 250V
- contact: AG 1000/1000
- operating temperature: + 5 ° C to + 30 ° C
- temperature difference: <1 ° C
- temperature gradient: 1 ° C / 10 min.
- degree of protection: IP20
Thermostat installation:
- the thermostat must be disconnected from the mains during installation
- reliable operation depends to a large extent on the correct mounting location
- the thermostat must be mounted in a place away from heat sources (radiator, television, refrigerator) and out of direct sunlight at least 1.5 m
- it is not recommended to install near the door, due to air flow
- the terminals of the connecting cables are located inside the thermostat
- to access the terminals, select the adjustment knob and remove the screws securing the cover
- connection is possible according to the enclosed diagram located in the package
Technical parameters:
- voltage: 16A 250V
- contact: AG 1000/1000
- operating temperature: + 5 ° C to + 30 ° C
- temperature difference: <1 ° C
- temperature gradient: 1 ° C / 10 min.